Iron filter

From Akvopedia
Revision as of 05:03, 16 November 2012 by Winona (talk | contribs) (Manuals, videos, and links)

Jump to: navigation, search
Iron filter icon.png
Building an iron filter.
Photo: PCWS

Iron is a naturally occurring element in the earth's crust and tends to leave a reddish-brown residue in water that tastes unpleasant and stains clothing, therefore removal is required. It is recommended, however, to check to see if the iron is geological or residue from water pumps with iron parts. If it is from the pump, replacement with a non-iron pump (i.e. stainless steel) could remove the iron from the water so that it is back to a drinkable standard. 1

There are a few different ways to remove iron, but generally filtration and biologically-enhanced methods are used and most practiced. Sometimes using multiple filters gives the best results. For instance, installing an upflow roughing filter before a slow sand filter increases iron removal to an acceptable level, even with high initial concentrations as high as 42mg/l (like in Uganda).1

IRF
The iron removal filter (IRF) is a cylinder built using ferrocement construction techniques. Inside, from top to bottom order, is a plastic basin full of charcoal, a layer of gravel, and an empty space for sedimentation. The media size is not critical, but if the grains are too fine (less than about 1mm diameter) the filter clogs very quickly.1 The water to be treated (in this model the water is assumed to be from a hand pump spout) first passes through the charcoal, aerating it, flows to the empty space at the bottom via a pipe where sedimentation of the precipitated iron takes place, then wells up through the gravel for filtration purposes. The finished water accumulates above the gravel filter, and this elevation enables users to draw it.

Biologically-enhanced method
Certain bacteria are capable of oxidising and immobilising iron. The bacteria responsible for the process appear to be natural inhabitants of the well environment and therefore, the microorganisms necessary to initiate the process are carried with the groundwater on to the filters. The active population of iron-oxidisers, which requires aeration in order to stimulate its growth, grows on the surface of the filter bed in the form of a slimy orange mat. It is within this zone of bacterial activity that the iron removal process appears to occur. Proponents of biological iron removal claim that this biologically-enhanced process is more efficient than the chemical process.

Construction, operations, and maintenance

IRF

To use it for the first time, the filter is filled with water and allowed to overflow a little. The first discharge is turbid from the gravel, but this clears up after a day or so of use. After placing their buckets under the tap, the users just pump the hand pump, and by gravity the water enters and flows through the filter, displacing the previous treated contents, which then overflows thru the taps into their buckets.

With no moving parts, operation is mainly trouble free. Philippine Center for Water and Sanitation (PCWS) and the organizations has trained and constructed 80 IRFs already. So far, there have been no reports of any breakdown yet.

It is possible that the charcoal may eventually clog up. The basin can then be removed from the IRF and cleaned by running water through it, assisting the process by manual agitation of the charcoal chunks.

The gravel may also eventually clog up occasionally. Cleaning it is also by manual agitation while recycling water through the IRF. A bucket is placed under the open tap and the contents are led by pouring, dipper by dipper, back through the charcoal basin. In cases where deposits have built up in the sedimentation space, a drain can be opened to clean this out. The worst that can happen is that the unit may eventually need overhauling. All parts are then taken out and cleaned, and clogs and leaks repaired.

Biologically-enhanced method

A biosand filter diagram. It can remove about 95% of iron (plus many other contaminants). Diagram: CAWST.

The key components of the filter are outlined in Diagram 1 (see below). Water from the handpump enters the filter and is directed onto an aeration tray. Water droplets fall from the aeration tray onto a few millimetres of standing water before infiltrating into the filter sand. A slotted drainpipe, set into a thin gravel blanket, collects the filtered water which exits via an outlet at a height of 0.45 m.

Surface area requirement

A filter of approximately 1 m2 surface area is necessary to deliver filtered water at a rate of about 0.25 l/s (assuming that guidelines on head and filter sand size / depth are followed).

Sand depth and size

A sand bed depth of 0.15 m is capable of consistently reducing iron concentrations of about 7 mg/l to <0.3 mg/l. Such consistent performance is achievable with a sand of 1.18 mm effective size. This sand needs a 0.05 m deep gravel support layer to ensure that it does not escape through the hacksaw cut slots in the drainage bar.

Head requirements and the need for ballast

The head needed to deliver an acceptable flow rate of 0.2-0.3 l/s in unclogged sand is 50 mm. This will increase as the filter clogs. To raise the water level from the top of the sand to a height of 50 mm requires 50 l of water to be pumped (assuming 1 m2 surface area), and therefore it would take 3 minutes of pumping just to reach the desired flow rate. This delay may be largely overcome by adding ballast to the filter. In a Ugandan trial, water-filled plastic bags were used as ballast. This approach worked well, taking only 29% more time to fill a jerrycan from the filter than it took directly from the handpump. It may be possible to improve this performance but further work is needed to assess the effect of ballast on the iron removal process.

Aeration

The water entering the filter must contain some oxygen in order to promote the oxidation of iron. Do some checks on the DO from the handpump itself. The water only needs to reach about 40-50% oxygen saturation and this may be achieved due to the aeration that naturally occurs in the handpump spout plus that provided by a perforated aeration plate.

Sketch diagram of the iron removal filter. Diagram: Dr Sean Tyrrel, Cranfield University.

For greater detail about construction as well as operation and maintenance (how to clean the filter, etc.), refer to Interim Design, Construction and Operation Guidelines for a Biologically-Enhanced Iron Removal Filter for Attachment to Handpumps.

Costs

Biologically-enhanced method

A prototype built in Uganda (circa 1997) cost about £235 of which £200 was the cost of the tank (which could be made more cheaply). The principal recurrent cost would be the employment of a caretaker. Even if a donor is prepared to pay for the filter itself, it may be that the community have to pay the caretaker’s wages. This is another example of where user motivation is important. Perhaps the caretaker could have a combined role for the upkeep of both the handpump and the filter. Such an arrangement would depend on how water supply is organised at a given location. The caretaker is likely to need additional, occasional support in the event of more serious problems with the operation and maintenance of the system.

Manuals, videos, and links

References

  1. 1.0 1.1 1.2 Iron and manganese removal. Andersson, Hanna and Jenny Johansson. Iron removal from groundwater in Rakai District, Uganda: a minor field study.

Acknowledgements