Leak Testing and Backfilling Procedures
#Backfill the rest of the way with clean soil and manually compact as above. Mound soil slightly around the tank to shed surface water and to avoid ponding of surface water over the tank.
#Check the soils over the tank frequently. Over the weeks or months after tank installation, some soils settling will occur. Fill depressions or fissures as soon as possible.
 
''NOTE: As soon as possible after the tank has hardened, add water to the tank and begin the backfilling procedure. This provides weight that can counteract buoyancy forces. This is especially important in areas where groundwater is high or surface waters can fill in tank holes.''
''[[Practitioner's Tool / Technology and Operation / Primary Treatment Methods| Back to Primary Treatment Methods]]''
''[[Practitioner's Tool / Technology and Operation|Back to Technology and Operation]]''
Akvopedia-spade, akvouser, bureaucrat, emailconfirmed, staff, susana-working-group-1, susana-working-group-10, susana-working-group-11, susana-working-group-12, susana-working-group-2, susana-working-group-3, susana-working-group-4, susana-working-group-5, susana-working-group-6, susana-working-group-7, susana-working-group-8, susana-working-group-9, susana-working-group-susana-member, administrator, widget editor